Models
Redundant Controller Systems
Host Interface | SAS 6 Gb | SAS + iSCSI | iSCSI 1 Gb | iSCSI 10 Gb | 8 Gb Fibre Channel | F/C + iSCSI |
---|---|---|---|---|---|---|
Models | VX-3434R | VX-3478R | VX-3452R | VX-3464R | VX-3428R | VX-3448R |
Number of Host Ports | 4 | 4 + 4 | 12 | 4 | 8 | 8 + 4 |
RAID 5/6: IOPS (R/W) | 140K / 60K | 137K / 52K | 101K / 54K | 85K / 36K | 148K / 73K | 148K / 58K |
RAID 5/6: Throughput MB/s. (R/W) | 2,677 / 1,187 | 2,484 / 1,181 | 944 / 585 | 1,516 / 734 | 2,847 / 1,074 | 2,642 / 1,083 |
Single Controller Systems
Host Interface | SAS 6 Gb | SAS + iSCSI | iSCSI 1 Gb | iSCSI 10 Gb | 8 Gb Fibre Channel | F/C + iSCSI |
---|---|---|---|---|---|---|
Models | VX-3432S | VX-3474S | VX-3456S | VX-3462S | VX-3424S | VX-3444S |
Number of Host Ports | 2 | 2 + 2 | 6 | 2 | 4 | 4 + 2 |
RAID 5/6: IOPS (R/W) | 60K / 42K | 70K / 48K | 87K / 47K | 41K / 27K | 87K / 65K | 80K / 57K |
RAID 5/6: Throughput MB/s. (R/W) | 1,366 / 883 | 1,217 / 724 | 447 / 304 | 833 / 413 | 1,558 / 1,078 | 1,388 / 884 |
Number of Total SAS/SSD Disks | 112 |
3.5” SAS/SATA Disks | SAS: 15K rpm: 300, 450, 600 GB – 7.2K rpm: 1, 2, 3 TB; SATA: 4 TB 7.2K rpm |
2.5” SAS Disks | 10K rpm: 300, 450, 600, 900 GB |
2.5” SSD Disks | SLC: 100, 200, 400 GB – MLC: 200, 400, 800 GB |
Compatibility | Supports any open O/S; Supports VMware, Citrix, Hyper-V |
Reliability | RAID 0, 1, 3, 5, 6, 10, 15, 16, 30, 50, 60; Hot swap components; Hot spare drive; Automatic rebuild; Path failover |
Manageability | FlashDisk Global Manager manages multiple FlashDisk units over network; Automated alerts |
Warranty and Service | One year warranty; On-site service; 24×7 automated “call home” to US call center; Live technical phone support |
Features
Compatibility
- Supports VMware, Citrix, Microsoft Virtual Servers and Applications
- Supports any open O/S
- No host software or drivers needed
- Cluster: Windows, Novell, UNIX, Ljnux . . .
Connectivity, Capacity & Scalability
- Supports up to 112 disks
- Up to 8 F/C 8 Gb, 4 SAS 6 Gb or 12 GbE hosts
- 2 GB of cache per controller, 4 GB optional
- Scales to 448 TB with 6 expansion shelves
Iometer Performance
-
Throughput MB/s: 2,847 read; 1,074 write
-
IOPS: 148K read; 73K write
Reliability & Serviceability
- RAID 6 dual parity data protection
- Hot-swappable drives, power supplies, fans, BBUs, AC inlets, optional controllers
- Hot spares with automatic drive rebuilds
- Supports drive path failover & load balancing
- No single point of failure configurations
Centralized & Remote Management
- FlashDisk Global Manager out-of-band storage services management over Ethernet
- Automatic event and alert notification
- FlashAlert 24-hour “call-home” service
VX-3400 virtualized tiered storage expands to 448 TB with 112 disks to 4 TB in seven shelves with 16 drives each. It provides performance, reliability, advanced storage services and features FlashD2D – a unique scheduled, zero-downtime disk-to-disk backup. Its FlashDisk Global Manager provides a centralized management pane for all FlashDisk VX Series systems installed and centralized event notifications. This makes it very easy to manage a large, flexible virtual and tiered storage pool including primary storage, snapshot images and mirror volumes. It offers storage based or server based replication (CA ARC-serve Replication) for business continuity and disaster recovery.
VX-3400 supports single or dual redundant controllers with mirrored cache for SAS, iSCSI, 10 GbE, Fibre Channel or “Multi-Protocol RAID” with either Fibre Channel or SAS plus iSCSI hosts.
The VX-3400 is a “SAN-In-A-Box” that can attach to multiple hosts without switches. FlashDisk delivers exceptional performance with nearly 2,900 MB per second data throughput using SAS 6 Gb disk drives and 48 Gb SAS backend expansion buses. High performance TrueRAID6, with dedicated hardware ASIC for high speed dual distributed parity, protects against two simultaneous drive failures and ensures fast and successful disk rebuilds.
Services
Storage Services | |
---|---|
Virtual Storage Pools | Create, expand, and delete storage volumes as requirements change to maximize storage utilization. |
Snapshots | Up to 256 snapshots per volume with 4,096 total snapshots and 256 volume copies. Mount and read snapshots, restore files and databases. Rollback to selected time. Server flush agent supports Windows and Linux applications. |
Thin Provisioning Option | Provides dynamic storage allocation and maximizes storage utilization. |
Remote Replication Option | Storage based replication for business continuity and disaster recovery. |
Mirroring | Create mirror volumes, split mirrors, fast resync for data redundancy, backup, data mining and analysis. |
Volume Copy | Reconstitute full volumes from snapshots, create multiple full versions to avoid overloading production. |
FlashD2D Backup | Scheduled zero-downtime tiered primary to secondary disk-to-disk backup. Enables off-line copy to tape. |
Global Management | Manage multiple FlashDisk VX Series systems from a single, easy to use GUI from any browser on the web. |
Storage Wizard | Wizard simplifies initial setup and enables advanced settings. |
Visual Calendar Scheduler | Schedules all storage services including snapshots, volume copies, split mirrors, fast resync and replication easily and intuitively. |
Specs
System Options | |
---|---|
Thin Provisioning | Enables high storage utilization with virtual storage on demand. |
Remote Replication | Available on “multi-protocol” models with added iSCSI replication ports. |
Advanced Storage Services | Increases snapshots from 64 to 256 per volume; from 1,024 to 4,096 total and increases volume copies from 64 to 256 total. |
LUN Masking | Enables volume protection needed in SAN environment. |
Cache upgrade | Expands 2 GB controller cache memory to 4 GB cache. |
External Options | |
---|---|
FlashNAS Appliance | High performance NAS filer with snapshots; CIFS/NFS/AFP; NSPF |
CA ARCserve Replication | Protects availability of systems, applications and data |
3U RAID Base Unit | |
---|---|
RAID controller | Single/Dual redundant 64-bit, 11th generation controller |
RAID levels supported | 0, 1, 3, 5, 6, 1+0, 15, 16, 30, 50, 60 |
Host interfaces | 6 Gb SAS, 8 Gb F/C, GbE, 10 GbE |
Expansion shelf interface | 6 Gb SAS, 4 lanes – 24 Gb per port – up to 48 Gb per array |
Number of drives – Total capacity | (16) 3.5” or 2.5” disks per base unit – 448 TB maximum |
On-line capacity expansion | Automatically adds new drives to existing array – “on-the-fly” |
Cache memory capacity | 2 GB, expandable to 4 GB per controller |
Non-volatile cache | Li-ION battery powered backup to flash memory |
Maximum LUNs | 1024 total, 64 per host ID |
Maximum number of hosts | 4 SAS, 64 iSCSI or 64 Fibre Channel |
LUN mapping/filtering | Configurable per logical partition |
Host adapters available for | PCI-X, PCI Express |
Power supplies and AC inlets | Dual hot-swap redundant 530 W each; dual AC inlets |
3U Expansion Shelf | |
---|---|
Expansion architecture | Single/Dual SAS (Serial Attach SCSI) bus |
Expansion shelf architecture | Multiplexed access to each drive within the shelf |
Maximum drives/capacity | (16) 3.5” or 2.5” disks per expansion shelf – 64 TB per shelf maximum |
Removable drive trays | Hot swappable; individual drive locks |
Power supplies | Dual hot-swappable; 530 Watts each |
Cooling system | Dual hot-swappable fan modules |
Active components | No active data path components on the midplane |
S.E.S. monitoring controllers | Dual, hot-swappable SCSI Enclosure Services modules |
Controls and Indicators | |
---|---|
LCD front operation panel | 2 x 16 character display, push button controls. |
LED indicators | LED power, battery, controller, and system status |
Alerting | Audible and visual alerts |
Component failure | Failure indication through LCD and GUI |
LCD front operating console | View/edit logical RAID/physical drives, setup hot-spare drives, map hosts, check parity, enable write-back cache, rebuild failed drive, view logs… |
Compatibility | |
---|---|
Operating systems | Supports 14 Operating Systems including Windows, Linux, and UNIX |
Platforms supported | Intel, SUN, HP, IBM RS-6000, Apple, SGI |
Cluster support | Supports 9 industry-standards including Windows, Linux, and Veritas |
Remote monitoring ports | RJ45 10/100 Ethernet |
Communication protocols | TCP/IP, SNMP, SSH |
Storage Management | |
---|---|
Event notification | Automatic event and problem alert notification |
FlashAlert call home service | 24-hour call center available for immediate action |
Manage out of band | Ethernet |
FlashDisk Global Manager GUI | Manage storage services of multiple FlashDisks from any web browser |
General | |
---|---|
Uninterruptible power supply | Required when using write-back cache |
Redundant AC power | Dual 90-260 VAC Inlet, 47-63 Hz |
Power consumption | 100 VAC @ 9A; 240 VAC @ 4.5 A; 530 W with PFC |
RAID unit dimensions | 5.1″h x 17.5″w x 19.2″d |
RAID unit weight | Approximately 77 lbs. fully loaded with drives |
Operating temperature | 0° to 40° C |
Cooling system | Two dual hot-swap, ball bearing blowers; <51 dB-A |
Compliance | FCC, UL, CE, CSA |
Warranty & Service | |
---|---|
Standard warranty | One year, next day on-site and toll-free hotline; Options up to 24×7 on-site |
Installation and service | On-site installation; 24×7 service available |